Media 000548514: Pelvis
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000548514: Pelvis
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000548514
Media type
Mesh
Object element or part
Pelvis
Object represented
Object taxonomy
Notaden bennetti
Object organization
Side
Midline
Orientation
--
Short description
Midline pelvis of Notaden bennetti
Full description
--
Creator
Fusco, Diana
Date created
August 01, 2023
Date uploaded
August 13, 2023
FILE OBJECT DETAILS Field Definitions
File name
cas_herp_78115_Notaden_bennetti_pelvis_M_ct.stl
File format(s)
STL
File size
13.4 MB
Points
140940
Polygons
282056
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9.990, 10.988, 13.261
Centroid coordinates
14.621, 15.804, 26.967
Units of point coordinates
No Value Entered, Millimeter Default
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
California Academy of Sciences
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
CABAH
Publisher
Ozboneviz
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
CAS:HERP:78115
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1500
Voltage
80
Power
0.0152
Amperage
190
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000049969: Element Unspecified [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000049969: Element Unspecified [CTImageSeries] [CT]
was processed
to create
derived
Media 000548514: Pelvis [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Fusco, Diana
Event date
August 01, 2023
Software
Materialise Mimics
Description
Segmentation
Description attachment
None