Media 000059739: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000059739
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Calumma hilleniusi
Object organization
Side
--
Orientation
--
Short description
Calumma hilleniusi
Full description
Calumma hilleniusi specimen indicated by radiopaque "hollow J" marker
Creator
--
Date created
--
Date uploaded
October 16, 2018

FILE OBJECT DETAILS Field Definitions

File name
Calumma-hilleniusi.zip
File format(s)
ZIP archive, JPEG
File size
92.9 MB
Image width
913
Image height
886
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.026200
Y pixel spacing
0.026200
Z pixel spacing
0.026200
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,251

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN, NSF DBI1701665, NSF DBI1702263
Publisher
--
Cite as
Christopher V. Anderson provided access to these dataoriginally appearing in MorphoSource , the collection of which was funded by University of South Dakota. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object CAS:HERP:86707 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Anderson, Christopher V.
Event date
--
Software
--
Description
Specimen indicated by radiopaque "hollow J" marker
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000059739: Element Unspecified [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Anderson, Christopher V.
Event date
--
Software
--
Description
Specimen indicated by radiopaque "hollow J" marker
Description attachment
None

Media produced by this event on MorphoSource

Media 000059739: Element Unspecified [CTImageSeries] [CT] (this media)