[General] Version=2.2.1.695 Version-pca=2 Comment= LoadDefault=1 [AutoScO] Active=1 ImgNr=8 ImageString=125:250:375:500:625:750:875:1000 Skip=10 [Geometry] FDD=598.82010000 FOD=149.99960000 Magnification=3.99214465 VoxelSizeX=0.02504919 VoxelSizeY=0.02504919 CalibValue=0.00000000 cx=1535.50000000 cy=1199.50000000 DetectorRot=0.00000000 Tilt=0.00000000 [CT] Type=0 NumberImages=1000 StartImg=1001 RotationSector=360.00000000 NoRotation=0 EstimatedTime=0 RemainingTime=1000 ScanTimeCmpl=1000 NrImgDone=1001 NrImgCmplScan=1001 RefDriveEnabled=0 SkipForNewInterval=10 UpdateView=1 SkipAcc=1 FreeRayFactor=1.00010000 Wnd_L=2959 Wnd_T=76 Wnd_R=3014 Wnd_B=110 Level=1513.00000000 [VSensor] EnableTiles=2 Start=0 NumTiles=1 Interval=60 Overlap=9 AdjustImg=1 SingleImgX=3072 [Trajectory] Active=0 [CalibValue] NumberImages=18 Averaging=2 Skip=3 [FastCT] Active=0 [Image] Top=0 Left=0 Bottom=2399 Right=3071 DimX=3072 DimY=2400 Rotation=0 MirrorX=0 MirrorY=0 BitPP=16 FreeRay=1577 [ImgProc] SwBin=1 AddSwBin=0 [Warmup] Enable=1 Counter=0 MaxTimes=15 TimeTrigOn=1 kV=185 Time=60 [Multiscan] Active=0 [Multiline] Installed=0 [CalibImages] MGainMode=0 MGainPoints=2 Avg=100 Skip=10 EnableAutoAcq=1 MGainVoltage=150:150: MGainCurrent=30:90: GainImg=S:\CT RECON S Drive Data\UCMP150687_erinaceid_rostrum_JODA\Raw and Reconstructed\UCMP150687_erinaceid_rostrum_JODA_bright_150kV_90uA_500ms_1Det.tif MGainImg=S:\CT RECON S Drive Data\UCMP150687_erinaceid_rostrum_JODA\Raw and Reconstructed\UCMP150687_erinaceid_rostrum_JODA_bright_150kV_90uA_500ms_1Det.tif OffsetImg=S:\CT RECON S Drive Data\UCMP150687_erinaceid_rostrum_JODA\Raw and Reconstructed\UCMP150687_erinaceid_rostrum_JODA_Dark_500.tif DefPixelImg=C:\Program Files\phoenix x-ray\datosx 2 acq\CalibrationImages\pixmask_B1x1_x3072_y2400.tif [SectorScan] Active=0 [DetectorShift] Enable=0 [Detector] InitTimeOut=120000 Name=dxr-500l PixelsizeX=0.10000000 PixelsizeY=0.10000000 NrPixelsX=3072 NrPixelsY=2400 Timing=0 TimingVal=500.000 Avg=2 Skip=1 Binning=0 BitPP=14 CameraGain=3 SatValue=15563 SatPixNrLimit=7372 [Xray] ComPort=0 Name=xs|180 hpnf ID=1813 InitTimeout=15000 Voltage=150 Current=90 Mode=0 Filter=0.1 mm Cu Collimation=0 WaitTime=5000 WaitForStable=20000 FocDistX=0.00000000 FocDistY=0.00000000 SpinStepkV=10 SpinStepuA=10 Macro=0 RestrictNumSpots=0 PreWarning=0 MinGainCurrent=20 [Cnc] InitTimeout=8000 CollisionDetection=1 JoyDriveDoorOpen=0 SecPosSample=120.00000000 MinSampleDetPos=180.00000000 EnableKeyboardJoy=0 KeyJoyVelocityFactor=0.25000000 [Axis] XSample=0.000000 YSample=165.000000 ZSample=149.999600 RSample=0.000000 TSample=0.000000 YTube=0.000000 ZTube=0.000000 XDetector=0.000000 YDetector=0.000000 ZDetector=598.820100 WDetector=0.000000 ColSlave=0.000000 [AcqSrvManager] RecvPcIp= ExePath=c:\Program Files\phoenix x-ray\datosx 2 acq\srv\dtxaSrv.exe [Net] Enable=0 ServerName= IP=