Media 000000565: Calcaneus
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000000565: Calcaneus
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000000565
Media type
Volumetric Image Series
Object element or part
calcaneus
Object represented
Object taxonomy
Marcgodinotius indicus
Object organization
Side
Unknown
Orientation
--
Short description
Zipped microCT image stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped microCT image stack Migrated MorphoSource 1 Media Group Title: Surface/Smooth Migrated MorphoSource 1 Media File Description: zipped image stack. TIFF format. Migrated MorphoSource 1 Media Group Description: Smooth
Creator
--
Date created
--
Date uploaded
August 14, 2013
FILE OBJECT DETAILS Field Definitions
File name
20945_ms_media_media_673_archive_.zip
File format(s)
ZIP archive, TIFF
File size
89.7 MB
Image width
294
Image height
314
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.015000
Y pixel spacing
0.015000
Z pixel spacing
0.015000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
595
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Doug Boyer
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Grant support for this scan:American Association of Physical Anthropology Professional Development Grant to DMB in 2009National Science Foundation (NSF) grant to D. Boyer and E. Seiffert: BCS 1317525 (formerly BCS 1125507)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in Boyer et al. (2013) NSF BCS 1317525. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
gu:1642
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
none
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000000565: Calcaneus [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000000565: Calcaneus [CTImageSeries] [Etc] (this media)