Media 000001073: Calcaneus
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000001073: Calcaneus
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000001073
Media type
Volumetric Image Series
Object element or part
Calcaneus
Object represented
Object taxonomy
Cantius ralstoni
Object organization
Side
Left
Orientation
--
Short description
Zipped microCT image stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped microCT image stack Migrated MorphoSource 1 Media Group Title: Cropped Surface/Smooth Migrated MorphoSource 1 Media File Description: Zipped image stack - TIFF format Migrated MorphoSource 1 Media Group Description: smooth crop.
Creator
--
Date created
--
Date uploaded
September 30, 2013
FILE OBJECT DETAILS Field Definitions
File name
34223_ms_media_media_1230_archive_.zip
File format(s)
ZIP archive, TIFF
File size
195 MB
Image width
387
Image height
496
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.020735
Y pixel spacing
0.020735
Z pixel spacing
0.020735
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
683
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Doug Boyer
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1317525 to DMB and ERS
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in NSF BCS 1317525. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ummp:vp:79150
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
James Thostenson
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1550
Voltage
100
Power
--
Amperage
120
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000001073: Calcaneus [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
James Thostenson
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000001073: Calcaneus [CTImageSeries] [Etc] (this media)