Media 000005959: Mandible
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000005959
Media type
Mesh
Object element or part
mandible
Object represented
Object taxonomy
Homo habilis
Side
Midline
Orientation
--
Short description
mesh file
Full description
Migrated MorphoSource 1 Media File Title: mesh file Migrated MorphoSource 1 Media Group Title: mesh file
Creator
--
Date created
--
Date uploaded
June 13, 2015

FILE OBJECT DETAILS Field Definitions

File name
OH-7_simp-flip_clean.ply
File format(s)
PLY
File size
52.5 MB
Points
721038
Polygons
1442072
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
75.237, 64.385, 45.538
Centroid coordinates
-2.977, 76.283, 28.341
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Duke SMIF
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in , the collection of which was funded by. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:CCC05 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Heather Krisjanson
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1900
Voltage
120
Power
0.01476
Amperage
123
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000005959: Mandible [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Heather Krisjanson
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000005959: Mandible [Mesh] [Etc] (this media)