Media 000015498: Lower M2
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Media 000015498: Lower M2
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000015498
Media type
Mesh
Object element or part
Lower M2
Object represented
Object taxonomy
Alouatta seniculus seniculus
Object organization
Side
Left
Orientation
--
Short description
Lower M2 Raw
Full description
Migrated MorphoSource 1 Media File Title: Lower M2 Raw Migrated MorphoSource 1 Media Group Title: Lower M2 Ply Files (analyzed in molaR paper) Migrated MorphoSource 1 Media Group Description: Modified from previously segmented lower M2 represented by morphosource media group M754-634
Creator
--
Date created
--
Date uploaded
August 04, 2016
FILE OBJECT DETAILS Field Definitions
File name
USNM-281673_Raw.ply
File format(s)
PLY
File size
40.4 MB
Points
575761
Polygons
1149657
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.462, 8.579, 4.779
Centroid coordinates
4.203, 15.081, 3.546
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Paul E. Morse provided access to these datawhich are derived from M754-634 provided by D.M. Boyer and first appeared in Pampush et al. (2016). Raw data collection was funded by the following grants: BCS-0129601, EAR-0308902, BCS-0622544, and DDIG 40761-0001. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
USNM:MAMM:USNM 281673
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
James D. Pampush; Paul E. Morse
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000015498: Lower M2 [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
James D. Pampush, Paul E. Morse
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000015498: Lower M2 [Mesh] [Etc] (this media)