Media 000018077: Lower Premolar
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000018077: Lower Premolar
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000018077
Media type
Volumetric Image Series
Object element or part
lower premolar
Object represented
Object taxonomy
Gorilla gorilla gorilla
Object organization
Side
Left
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: CT volume file and ply files of raw and patched surfaces
Creator
--
Date created
--
Date uploaded
October 24, 2016
FILE OBJECT DETAILS Field Definitions
File name
Bf02_AMNH_200581_Gorilla_gorilla_p4.zip
File format(s)
ZIP archive, TIFF
File size
88.1 MB
Image width
408
Image height
408
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.039000
Y pixel spacing
0.039000
Z pixel spacing
0.039000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
360
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical vivaCT 75, Stony Brook University Center for Biotechnology (Stony Brook University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
A Leakey Foundation Grant and NSF BCS 1304045 to E. St. Clair and D. M. Boyer and NSF BCS 1552848 to D. M. Boyer
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data NSF BCS 1304045. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
AMNH:Mammals:M-200518
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer; Claire Carney
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000018077: Lower Premolar [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Doug Boyer, Claire Carney
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000018077: Lower Premolar [CTImageSeries] [Etc] (this media)