Media 000022647: Dicect 16bit Tiffs
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000022647: Dicect 16bit Tiffs
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000022647
Media type
Volumetric Image Series
Object element or part
DICECT 16bit tiffs
Object represented
Object taxonomy
Pipa parva
Object organization
Side
--
Orientation
--
Short description
DiceCT Z-stack
Full description
Migrated MorphoSource 1 Media File Title: DiceCT Z-stack Migrated MorphoSource 1 Media Group Title: DICECT of UF37924 Pipa parva
Creator
--
Date created
--
Date uploaded
February 14, 2017
FILE OBJECT DETAILS Field Definitions
File name
UF37924.zip
File format(s)
ZIP archive, TIFF
File size
2.89 GB
Image width
1132
Image height
784
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.021887
Y pixel spacing
0.021887
Z pixel spacing
0.021887
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,022
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
University of Florida
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Herp:37924
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1600
Voltage
120
Power
0.0216
Amperage
180
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000022647: Dicect 16bit Tiffs [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000022647: Dicect 16bit Tiffs [CTImageSeries] [Etc] (this media)