Media 000031061: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000031061: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
Project
· Public
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000031061
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Pseudotylosurus angusticeps
Object organization
Side
--
Orientation
--
Short description
Pseudotylosurus angusticeps -Images/ slice data/ log file
Full description
Migrated MorphoSource 1 Media File Title: Pseudotylosurus angusticeps -Images/ slice data/ log file Migrated MorphoSource 1 Media Group Title: Pseudotylosurus angusticeps -Images/ slice data/ log file
Creator
--
Date created
--
Date uploaded
August 15, 2017
FILE OBJECT DETAILS Field Definitions
File name
Kolmann.NeedlerCan5.Pseudotylosurus_angusticeps.7983.zip
File format(s)
ZIP archive, JPEG
File size
318 MB
Image width
688
Image height
379
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.031070
Y pixel spacing
0.031070
Z pixel spacing
0.031070
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Cornell University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701665
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
cumv:fish:878505
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000031061: Element Unspecified [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000031061: Element Unspecified [CTImageSeries] [Etc] (this media)