Media 000036105: Element Unspecified
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000036105: Element Unspecified
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000036105
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Japalura polygonata
Object organization
Side
--
Orientation
--
Short description
STL of skull
Full description
Migrated MorphoSource 1 Media File Title: STL of skull Migrated MorphoSource 1 Media Group Title: CT scan of UF126290, Japalura polygonata
Creator
--
Date created
--
Date uploaded
November 05, 2017
FILE OBJECT DETAILS Field Definitions
File name
UF126290_skull.stl
File format(s)
STL
File size
106 MB
Points
1112210
Polygons
2229578
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.078, 14.837, 19.092
Centroid coordinates
-7.220, 2.035, -1.707
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Florida Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
oVert Thematic Collections Network (TCN), NSF DBI-1701714
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Herp:126290
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1200
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000040808: 16bit Tiffs [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000040808: 16bit Tiffs [CTImageSeries] [Etc]
was processed
to create
derived
Media 000036105: Element Unspecified [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000036105: Element Unspecified [Mesh] [Etc] (this media)