Media 000049719: Element Unspecified
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000049719: Element Unspecified
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000049719
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Eupolybothrus liburnicus
Object organization
Side
NotApplicable
Orientation
--
Short description
CPH 538 overview scan - reconstructed slices
Full description
Migrated MorphoSource 1 Media File Title: CPH 538 overview scan - reconstructed slices Migrated MorphoSource 1 Media Group Title: MicroCT images of paratype CHP538 Migrated MorphoSource 1 Media File Description: SkyScan 1174 scan of Eupolybothrus female paratype CPH 538. Scan metadata are in folder CPH538_scan_notes.
Creator
--
Date created
--
Date uploaded
June 07, 2018
FILE OBJECT DETAILS Field Definitions
File name
CPH538_IKI_18-3um_16bTIFF.zip
File format(s)
ZIP archive, TIFF
File size
1.86 GB
Image width
877
Image height
2010
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
--
Y pixel spacing
--
Z pixel spacing
--
Pixel spacing units
--
Slice thickness
--
Number of images in set
652
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1174, Laboratory for Vertebrate Paleontology (University of Alberta Museums)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
N. Akkari, A. Ganske, A. Komerički, B. Metscher
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
cbss:chp:538
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Laboratory for Vertebrate Paleontology (University of Alberta Museums)
Creator
Dr. Brian Metscher
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000049719: Element Unspecified [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Dr. Brian Metscher
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000049719: Element Unspecified [CTImageSeries] [Etc] (this media)