Media 000054210: Hamate
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000054210
Media type
Volumetric Image Series
Object element or part
Hamate
Object represented
Object taxonomy
Plesiadapis cookei
Object organization
Side
Left
Orientation
--
Short description
Zipped dcm stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped dcm stack Migrated MorphoSource 1 Media Group Title: Micro CT volume and derivative mesh Migrated MorphoSource 1 Media File Description: correct chirality / Boyer and Gingerich (2018: Figure 43C) Migrated MorphoSource 1 Media Group Description: correct chirality / Boyer and Gingerich (2018: Figure 43C)
Creator
--
Date created
--
Date uploaded
July 13, 2018

FILE OBJECT DETAILS Field Definitions

File name
Boyer_UM-89970_hand_bonesII_Hamate_left.zip
File format(s)
ZIP archive, DICOM
File size
22.4 MB
Image width
322
Image height
291
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.016903
Y pixel spacing
0.016903
Z pixel spacing
0.016903
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
354

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
University of Michigan Museum of Paleontology
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1440742 (to DM Boyer and GF Gunnell), BCS 1440588 (to JI Bloch), and BCS 1552848 (to DM Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in , the collection of which was funded by NSF BCS 1440742, BCS 1440588, BCS 1552848. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UMMP:VP:87990 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Jong Gwan Lee
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
2000
Voltage
140
Power
0.01414
Amperage
101
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000054210: Hamate [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Doug Boyer, Jong Gwan Lee
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000054210: Hamate [CTImageSeries] [Etc] (this media)