Media 000054462: Intermediate Phalanx, Manual
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000054462: Intermediate Phalanx, Manual
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000054462
Media type
Mesh
Object element or part
Intermediate phalanx, manual
Object represented
Object taxonomy
Plesiadapis cookei
Object organization
Side
Unknown
Orientation
--
Short description
Smooth surface mesh
Full description
Migrated MorphoSource 1 Media File Title: Smooth surface mesh Migrated MorphoSource 1 Media Group Title: Micro CT volume and derivative mesh Migrated MorphoSource 1 Media File Description: correct chirality / Boyer and Gingerich (2018: Figure 53C) Migrated MorphoSource 1 Media Group Description: correct chirality / Boyer and Gingerich (2018: Figure 53C)
Creator
--
Date created
--
Date uploaded
July 17, 2018
FILE OBJECT DETAILS Field Definitions
File name
Boyer_UM-89970_R_hand_bones_correct-chirality_Intermediate-phalanx--b-.ply
File format(s)
PLY
File size
16.6 MB
Points
235466
Polygons
470928
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3.982, 3.309, 8.082
Centroid coordinates
19.691, 14.361, 20.463
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
University of Michigan Museum of Paleontology
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1440742 (to DM Boyer and GF Gunnell), BCS 1440588 (to JI Bloch), and BCS 1552848 (to DM Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in , the collection of which was funded by NSF BCS 1440742, BCS 1440588, BCS 1552848. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UMMP:VP:87990
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Jong Gwan Lee
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
2000
Voltage
140
Power
0.01414
Amperage
101
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000054461: Intermediate Phalanx, Manual [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Doug Boyer, Jong Gwan Lee
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000054461: Intermediate Phalanx, Manual [CTImageSeries] [Etc]
was processed
to create
derived
Media 000054462: Intermediate Phalanx, Manual [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Doug Boyer, Jong Gwan Lee
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000054462: Intermediate Phalanx, Manual [Mesh] [Etc] (this media)