Media 000054742: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000054742
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Sylvilagus bachmani riparius
Side
--
Orientation
--
Short description
tiff stack
Full description
Migrated MorphoSource 1 Media File Title: tiff stack Migrated MorphoSource 1 Media Group Title: tiff stack Migrated MorphoSource 1 Media Group Description: Correct chirality.
Creator
--
Date created
--
Date uploaded
July 20, 2018

FILE OBJECT DETAILS Field Definitions

File name
MVZ_228957_tiff.zip
File format(s)
ZIP archive, TIFF
File size
728 MB
Image width
1002
Image height
1254
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.044698
Y pixel spacing
0.044698
Z pixel spacing
0.044698
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,461

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1552848 (to D M Boyer), NSF DBI 1458192 (to G F Gunnell)
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MVZ:Mamm:MVZ:Mamm:228957 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Arianna Harrington
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2000
Voltage
157
Power
--
Amperage
90
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000054742: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Arianna Harrington
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000054742: Skull [CTImageSeries] [CT] (this media)