Media 000055454: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000055454: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000055454
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Sternarchorhynchus marreroi
Object organization
Side
--
Orientation
--
Short description
Sternarchorhynchus marreroi
Full description
Migrated MorphoSource 1 Media File Title: Sternarchorhynchus marreroi Migrated MorphoSource 1 Media Group Title: Sternarchorhynchus marreroi
Creator
--
Date created
--
Date uploaded
July 26, 2018
FILE OBJECT DETAILS Field Definitions
File name
Sternarchorhynchus-marreroi.zip
File format(s)
ZIP archive, JPEG
File size
56.2 MB
Image width
684
Image height
1003
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.033900
Y pixel spacing
0.033900
Z pixel spacing
0.033900
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,616
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Academy of Natural Sciences of Drexel University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN, NSF DBI1701665, NSF DBI1701943
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Kory Evans-Jackson provided access to these dataoriginally appearing in , the collection of which was funded by. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ANSP:FISH:198345
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
70
Power
--
Amperage
114
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000055454: Element Unspecified [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource