Media 000055843: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000055843
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Dactyloteuthis Dactyloteuthis hebetata
Side
NotApplicable
Orientation
--
Short description
raw data 4
Full description
Migrated MorphoSource 1 Media File Title: raw data 4 Migrated MorphoSource 1 Media Group Title: raw data 4
Creator
--
Date created
--
Date uploaded
August 03, 2018

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
729 MB
Image width
980
Image height
1000
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
37.73 micron
Y pixel spacing
37.73 micron
Z pixel spacing
37.73 micron
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
811

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s 240, Paleontology Institute (Friedrich-Alexander-Universität Erlangen-Nürnberg)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object snsb-bspg:2018 ix:4 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Paleontology Institute (Friedrich-Alexander-Universität Erlangen-Nürnberg)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
800
Voltage
190
Power
--
Amperage
190
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000055843: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000055843: Element Unspecified [CTImageSeries] [Etc] (this media)