Media 000056554: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000056554: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000056554
Media type
Volumetric Image Series
Object element or part
Skull
Object represented
Object taxonomy
Cebus Sp.
Object organization
Side
--
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: microCT Volume File Migrated MorphoSource 1 Media File Description: Correct chirality Migrated MorphoSource 1 Media Group Description: Correct chirality
Creator
--
Date created
--
Date uploaded
August 16, 2018
FILE OBJECT DETAILS Field Definitions
File name
Cebus-1819-Skull.zip
File format(s)
ZIP archive, TIFF
File size
1.82 GB
Image width
1458
Image height
1242
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.051031
Y pixel spacing
0.051031
Z pixel spacing
0.051031
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,800
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Stony Brook University, Dept of Anatomical Sciences
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1552848; oVert; DBI-1701714
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer & Stephanie Maiolino provided access to these data , the collection of which was funded by NSF BCS 1552848. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
sbu:1819
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
135
Power
0.016875
Amperage
125
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000056554: Skull [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000056554: Skull [CTImageSeries] [Etc] (this media)