Media 000062475: Femur, Distal
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000062475: Femur, Distal
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000062475
Media type
Volumetric Image Series
Object element or part
Femur, Distal
Object represented
Object taxonomy
Homo sapiens
Object organization
Side
Left
Orientation
--
Short description
TIFF stack of AFIP 0385009
Full description
Migrated MorphoSource 1 Media File Title: TIFF stack of AFIP 0385009 Migrated MorphoSource 1 Media Group Title: Femur with Civil War Era GSW Migrated MorphoSource 1 Media File Description: Brian Spatola
Creator
--
Date created
--
Date uploaded
October 24, 2018
FILE OBJECT DETAILS Field Definitions
File name
AFIP-0385009-TIFF.zip
File format(s)
ZIP archive, TIFF
File size
435 MB
Image width
804
Image height
713
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.118400
Y pixel spacing
0.118400
Z pixel spacing
0.118400
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,694
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, Federal Bureau of Investigation (Federal Bureau of Investigation)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nmhm:cw:AFIP-0385009
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Federal Bureau of Investigation (Federal Bureau of Investigation)
Creator
--
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
4
Projections
1000
Voltage
150
Power
--
Amperage
225
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000062475: Femur, Distal [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None