Media 000064939: Whole Specimen
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000064939: Whole Specimen
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000064939
Media type
Volumetric Image Series
Object element or part
Whole specimen
Object represented
Object taxonomy
Unknown sp.
Object organization
Side
NotApplicable
Orientation
--
Short description
BMP Image Stack (zipped)
Full description
Migrated MorphoSource 1 Media File Title: BMP Image Stack (zipped) Migrated MorphoSource 1 Media Group Title: MircoCT image stack and derivatives of F27 Migrated MorphoSource 1 Media File Description: BMP image stack (1319 slices) extracted from the raw .RAW file created by the reconstruction of the sinograms/projections. These images have been enhanced for 'Brightness/Contrast' (min: 2022
Creator
--
Date created
--
Date uploaded
December 02, 2018
FILE OBJECT DETAILS Field Definitions
File name
BMPStack.zip
File format(s)
ZIP archive, BMP
File size
1.97 GB
Image width
1647
Image height
1608
Color space
--
Color depth
8
Compression
None; BI_RGB; 0
X pixel spacing
0.008327
Y pixel spacing
0.008327
Z pixel spacing
0.008327
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,250
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Alan R.T. Spencer
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Alan R.T. Spencer provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mhnan:2011-pb:245
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.708
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
3142
Voltage
200
Power
0.038
Amperage
190
Surrounding material
Oasis foam
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000064939: Whole Specimen [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000064939: Whole Specimen [CTImageSeries] [CT] (this media)