Media 000065222: Cranium
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000065222
Media type
Volumetric Image Series
Object element or part
cranium
Object represented
Object taxonomy
Shoshonius cooperi
Side
Midline
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: microCT Volume and Derivatives Migrated MorphoSource 1 Media File Description: correct chirality Migrated MorphoSource 1 Media Group Description: correct chirality
Creator
--
Date created
--
Date uploaded
December 06, 2018

FILE OBJECT DETAILS Field Definitions

File name
CM-60494_shoshonius-cranium.zip
File format(s)
ZIP archive, TIFF
File size
3.54 GB
Image width
1326
Image height
924
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.015700
Y pixel spacing
0.015700
Z pixel spacing
0.015700
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,789

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Carnegie Museum of Natural History, Section of Vertebrate Paleontoloogy
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: E. Christopher Kirk provided access to these data , the collection of which was funded by NSF. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object cm:vertpaleo:060494 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2499
Voltage
130
Power
--
Amperage
140
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000065222: Cranium [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000065222: Cranium [CTImageSeries] [Etc] (this media)