Media 000065965: Element Unspecified
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000065965
Media type
Volumetric Image Series
Object element or part
--
Object taxonomy
Bombus terrestris
Side
--
Orientation
--
Short description
label stack
Full description
Migrated MorphoSource 1 Media File Title: label stack Migrated MorphoSource 1 Media Group Title: Bumblebee female ocelli Migrated MorphoSource 1 Media File Description: scan 77979 Migrated MorphoSource 1 Media Group Description: Scan 77979
Creator
--
Date created
--
Date uploaded
January 04, 2019

FILE OBJECT DETAILS Field Definitions

File name
77979_BT_F_ocelli_labelStack.zip
File format(s)
ZIP archive, TIFF
File size
293 KB
Image width
284
Image height
656
Color space
RGB Palette
Color depth
8
Compression
--
X pixel spacing
0.000813
Y pixel spacing
0.000813
Z pixel spacing
0.000813
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
163

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Diamond Manchester Imaging Branchline (I13-2), I13: X-ray Imaging and Coherence (Diamond Light Source Ltd)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object lu:bvg:4_16-BT_F_ocelli_dark2 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
I13: X-ray Imaging and Coherence (Diamond Light Source Ltd)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.05
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
4001
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000065965: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000065965: Element Unspecified [CTImageSeries] [Etc] (this media)