Media 000072975: 3 D Surface Image Of Endocast Stl
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000072975: 3 D Surface Image Of Endocast Stl
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000072975
Media type
Mesh
Object element or part
3D surface image of Endocast - STL
Object represented
Object taxonomy
Alligator mississippiensis
Object organization
Side
--
Orientation
--
Short description
Visible Interactive Alligator Endocast
Full description
Migrated MorphoSource 1 Media File Title: Visible Interactive Alligator Endocast Migrated MorphoSource 1 Media Group Title: Alligator mississippiensis OUVC 11415 - CT data of head and neck of subadult individual Migrated MorphoSource 1 Media File Description: MicroCT scan data in STL format Migrated MorphoSource 1 Media Group Description: zip file of CT scan data in DICOM format
Creator
--
Date created
--
Date uploaded
April 01, 2019
FILE OBJECT DETAILS Field Definitions
File name
Alligator-Endocast-OUVC-11415---prescan_Octopus-recon-canonical.view.resampled.labels.stl
File format(s)
STL
File size
22.7 MB
Points
237549
Polygons
475082
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
16.420, 18.072, 42.891
Centroid coordinates
39.780, 28.265, 30.673
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore Locus in vivo, Ohio University MicroCT Facility (Ohio University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF Grants IOB-0517257, IOS-1050154, IOS-1456503
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: WitmerLab at Ohio University provided access to these dataoriginally appearing on the Visible Interactive Alligator website, , the collection of which was funded by NSF. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ouvc:11415
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Ryan Ridgely
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.020
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
4
Projections
1200
Voltage
120
Power
3.84
Amperage
32000
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000072948: Head And Neck [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Ryan Ridgely
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000072948: Head And Neck [CTImageSeries] [Etc]
was processed
to create
derived
Media 000072975: 3 D Surface Image Of Endocast Stl [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Ryan Ridgely
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000072975: 3 D Surface Image Of Endocast Stl [Mesh] [Etc] (this media)