Media 000073610: 3 D Surface Image Of Full Body Stl
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000073610: 3 D Surface Image Of Full Body Stl
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000073610
Media type
Mesh
Object element or part
3D surface image of Full-body - STL
Object represented
Object taxonomy
Gavia immer
Object organization
Side
--
Orientation
--
Short description
Common loon Full-body STL
Full description
Migrated MorphoSource 1 Media File Title: Common loon Full-body STL Migrated MorphoSource 1 Media Group Title: Common loon (Gavia immer), OUVC 10719. Diagnostic (hospital) scan of full body. Migrated MorphoSource 1 Media File Description: CT scan data in STL format Migrated MorphoSource 1 Media Group Description: zip file of diagnostic (hospital) scan data in DICOM format
Creator
--
Date created
--
Date uploaded
April 05, 2019
FILE OBJECT DETAILS Field Definitions
File name
WitmerLab_common-loon_full-body_OUVC10719.surf.stl
File format(s)
STL
File size
168 MB
Points
1737225
Polygons
3506564
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
184.047, 108.272, 833.862
Centroid coordinates
5.055, -7.390, 1366.989
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Toshiba Aquilion 64 CT Scanner, OhioHealth O'Bleness Hospital (OhioHealth O'Bleness Hospital)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF Grants IOB-0517257, IOS-1050154, IOS-1456503
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: WitmerLab at Ohio University provided access to these data , the collection of which was funded by NSF. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ouvc:10719
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
OhioHealth O'Bleness Hospital (OhioHealth O'Bleness Hospital)
Creator
Heather Rockhold, OhioHealth O'Bleness Hospital
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.75
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
120
Power
0.036
Amperage
360000
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000073761: Full Body Scan & µct Scan Of Head [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Heather Rockhold, OhioHealth O'Bleness Hospital
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000073761: Full Body Scan & µct Scan Of Head [CTImageSeries] [Etc]
was processed
to create
derived
Media 000073610: 3 D Surface Image Of Full Body Stl [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Heather Rockhold, OhioHealth O'Bleness Hospital
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000073610: 3 D Surface Image Of Full Body Stl [Mesh] [Etc] (this media)