Media 000074755: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000074755: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000074755
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Eleothreptus anomalus
Object organization
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
April 09, 2019
FILE OBJECT DETAILS Field Definitions
File name
KU_B_91247_Eleothreptus_ImageStack.zip
File format(s)
ZIP archive, TIFF
File size
240 MB
Image width
594
Image height
486
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.083365
Y pixel spacing
0.083365
Z pixel spacing
0.083365
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,924
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Kansas Natural History Museum
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1702421; NSF DBI-1701932; NSF DBI-1701714
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of Kansas Natural History Museum provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
KU:KUO:91247
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Stephanie Baumgart, Daryl Coldren, April Neander
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.200096
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
800
Voltage
110
Power
0.033
Amperage
300
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000074755: Element Unspecified [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Stephanie Baumgart, Daryl Coldren, April Neander
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000074755: Element Unspecified [CTImageSeries] [CT] (this media)