Media 000074918: Whole Body
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000074918: Whole Body
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000074918
Media type
Mesh
Object element or part
Whole body
Object represented
Object taxonomy
Xantusia riversiana
Object organization
Side
--
Orientation
--
Short description
mesh file (STL)
Full description
Migrated MorphoSource 1 Media File Title: mesh file (STL) Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
April 11, 2019
FILE OBJECT DETAILS Field Definitions
File name
MVZ228776.stl
File format(s)
STL
File size
584 MB
Points
1574006
Polygons
3148252
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
40.299, 22.639, 149.664
Centroid coordinates
0.768, -0.048, -31.496
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MVZ:Herp:MVZ:Herp:228776
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Event date
April 11, 2019
Software
VG Studio Max
Description
--
Description attachment
None
Reference attachment
None
Exposure time
200 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
800
Voltage
80 kV
Power
--
Amperage
200 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000636013: Whole Body [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Jaimi Gray
Event date
June 10, 2024
Software
VG Studio Max
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000636013: Whole Body [CTImageSeries] [CT]
was processed
to create
derived
Media 000074918: Whole Body [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Daniel Paluh
Event date
--
Software
VG Studio Max
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000074918: Whole Body [Mesh] [Etc] (this media)