Media 000078306: Ectocuneiform
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000078306: Ectocuneiform
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000078306
Media type
Mesh
Object element or part
Ectocuneiform
Object represented
Object taxonomy
Pan troglodytes schweeinfurthii
Object organization
Side
Left
Orientation
--
Short description
Smooth Surface Mesh
Full description
Migrated MorphoSource 1 Media File Title: Smooth Surface Mesh Migrated MorphoSource 1 Media Group Title: microCT Volume File and Derivative Mesh Files Migrated MorphoSource 1 Media File Description: Correct chirality Migrated MorphoSource 1 Media Group Description: Correct chirality
Creator
--
Date created
--
Date uploaded
May 22, 2019
FILE OBJECT DETAILS Field Definitions
File name
Aguilar_AMNH_51202_pan_L_cuneiform_A_.smooth.ply
File format(s)
PLY
File size
35.9 MB
Points
500000
Polygons
1000000
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.950, 15.457, 17.295
Centroid coordinates
6.193, 8.156, 10.198
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
AMNH:Mammals:M-51202
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
115
Power
0.014029999999999999
Amperage
122
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000078305: Ectouneiform [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000078305: Ectouneiform [CTImageSeries] [Etc]
was processed
to create
derived
Media 000078306: Ectocuneiform [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000078306: Ectocuneiform [Mesh] [Etc] (this media)