Media 000079798: Basisphenoid
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000079798: Basisphenoid
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000079798
Media type
Mesh
Object element or part
Basisphenoid
Object represented
Object taxonomy
Canis lupus familiaris
Object organization
Side
--
Orientation
--
Short description
Smooth Surface Mesh
Full description
Migrated MorphoSource 1 Media File Title: Smooth Surface Mesh Migrated MorphoSource 1 Media Group Title: Micro CT volume and surface rendering Migrated MorphoSource 1 Media Group Description: Opposite chirality
Creator
--
Date created
--
Date uploaded
June 05, 2019
FILE OBJECT DETAILS Field Definitions
File name
Basisphenoid.ply
File format(s)
PLY
File size
2.6 MB
Points
39468
Polygons
78944
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5.943, 6.135, 7.851
Centroid coordinates
55.436, 87.425, 119.806
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
SMIF Undergraduate User Program grant
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Peishu Li provided access to these data , the collection of which was funded by SMIF Undergraduate User Program grant. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ncsu:cvm:1
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Peishu Li
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
4
Projections
2200
Voltage
180
Power
0.024480000000000002
Amperage
136
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000063300: Full Skeleton [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Peishu Li
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000063300: Full Skeleton [CTImageSeries] [Etc]
was processed
to create
derived
Media 000079798: Basisphenoid [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Peishu Li
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000079798: Basisphenoid [Mesh] [Etc] (this media)