Media 000081138: Left Pedal Phalanx Ii 2
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000081138: Left Pedal Phalanx Ii 2
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000081138
Media type
Volumetric Image Series
Object element or part
left pedal phalanx II-2
Object represented
Object taxonomy
Rahonavis ostromi
Object organization
Side
Left
Orientation
--
Short description
UA 8656 left pedal phalanx II-2
Full description
Migrated MorphoSource 1 Media File Title: UA 8656 left pedal phalanx II-2 Migrated MorphoSource 1 Media Group Title: micro-CT volume data and polygon derivative
Creator
--
Date created
--
Date uploaded
June 17, 2019
FILE OBJECT DETAILS Field Definitions
File name
UA_8656_left_pedal_phalanx_II-2-DICOM.zip
File format(s)
ZIP archive, DICOM
File size
9.82 MB
Image width
163
Image height
128
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.044780
Y pixel spacing
0.044780
Z pixel spacing
0.044780
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
277
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore Locus in vivo, Ohio University MicroCT Facility (Ohio University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Patrick O'Connor
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR-1123642
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Patrick O'Connor and colleagues provided access to these datapublished in conjunction with Forster et al. 2020. with funding from the National Science Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ua:8656
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Patrick O'Connor
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
7
Projections
--
Voltage
80
Power
0.003984
Amperage
49.8
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000081138: Left Pedal Phalanx Ii 2 [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Patrick O'Connor
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000081138: Left Pedal Phalanx Ii 2 [CTImageSeries] [Etc] (this media)