Media 000081530: Head And Neck
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000081530
Media type
Volumetric Image Series
Object element or part
head and neck
Object represented
Object taxonomy
Phalacrocorax auritus
Side
--
Orientation
--
Short description
Double-crested Cormorant (Phalacrocorax auritus), OUVC 10847, prediceCT scan of head and neck
Full description
Migrated MorphoSource 1 Media File Title: Double-crested Cormorant (Phalacrocorax auritus), OUVC 10847, prediceCT scan of head and neck Migrated MorphoSource 1 Media Group Title: Double-crested Cormorant (Phalacrocorax auritus), OUVC 10847, prediceCT scan of head and neck Migrated MorphoSource 1 Media Group Description: zip file of pre-diceCT microCT scan data in TIFF format
Creator
--
Date created
--
Date uploaded
June 19, 2019

FILE OBJECT DETAILS Field Definitions

File name
WitmerLab_Phalacrocorax_auritus_OUVC10847_pre-diceCT_TIFF.zip
File format(s)
ZIP archive, TIFF
File size
3.62 GB
Image width
779
Image height
967
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
--
Y pixel spacing
--
Z pixel spacing
--
Pixel spacing units
--
Slice thickness
--
Number of images in set
3,504

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore CT 120 in vivo, Ohio University MicroCT Facility (Ohio University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF Grants IOB-0517257, IOS-1050154, IOS-1456503
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: WitmerLab at Ohio University provided access to these data , the collection of which was funded by NSF. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ouvc:10847 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Ryan Ridgely
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000081530: Head And Neck [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Ryan Ridgely
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000081530: Head And Neck [CTImageSeries] [Etc] (this media)