Media 000084086: Humerus
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000084086: Humerus
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000084086
Media type
Mesh
Object element or part
humerus
Object represented
Object taxonomy
Rahonavis ostromi
Object organization
Side
Right
Orientation
--
Short description
UA 9604 partial right humerus
Full description
Migrated MorphoSource 1 Media File Title: UA 9604 partial right humerus Migrated MorphoSource 1 Media Group Title: micro-CT volume data and polygon derivative
Creator
--
Date created
--
Date uploaded
August 01, 2019
FILE OBJECT DETAILS Field Definitions
File name
FMNH_PA_746.ply
File format(s)
PLY
File size
178 MB
Points
2332698
Polygons
4665622
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
17.930, 11.043, 48.156
Centroid coordinates
15.263, 8.365, 62.922
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore CT 120 in vivo, Ohio University MicroCT Facility (Ohio University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Patrick O'Connor
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR-1525915
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Patrick O'Connor and colleagues provided access to these datapublished in conjunction with Forster et al. 2020. with funding from the National Science Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ua:9604
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Ryan Ridgley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.02
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
120
Power
0.0038399999999999997
Amperage
32
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000084087: Humerus [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Ryan Ridgley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000084087: Humerus [CTImageSeries] [Etc]
was processed
to create
derived
Media 000084086: Humerus [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Ryan Ridgley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000084086: Humerus [Mesh] [Etc] (this media)