Media 000085463: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000085463: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000085463
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Aneides aeneus
Object organization
Side
--
Orientation
--
Short description
Aneides_aeneus_usnm201022
Full description
Migrated MorphoSource 1 Media File Title: Aneides_aeneus_usnm201022 Migrated MorphoSource 1 Media Group Title: Skull of Aneides aeneus (USNM 201022) Migrated MorphoSource 1 Media Group Description: DICOM image stack
Creator
--
Date created
--
Date uploaded
August 31, 2019
FILE OBJECT DETAILS Field Definitions
File name
A_aeneus_usnm201022.zip
File format(s)
ZIP archive, DICOM
File size
591 MB
Image width
485
Image height
622
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.014000
Y pixel spacing
0.014000
Z pixel spacing
0.014000
Pixel spacing units
Mm
Slice thickness
0.0139997
Number of images in set
1,304
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Somatom Emotion 6-slice scanner, Smithsonian Institution Bio-Imaging Research (SIBIR) Center (National Museum of Natural History, Smithsonian Institution)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Grace Capshaw provided access to these dataoriginally appearing in Capshaw et al 2019 with funding provided by NIDCD/NIH T32 DC-000046 to the University of Maryland's Center for Comparative and Evolutionary Biology of Hearing, and by DC-000436 to C.E. Carr. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
USNM:HERP:USNM 201022
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Smithsonian Institution Bio-Imaging Research (SIBIR) Center (National Museum of Natural History, Smithsonian Institution)
Creator
Jennifer J. Hill
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
200
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2400
Voltage
90
Power
0.015300000000000001
Amperage
170
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000085463: Element Unspecified [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Jennifer J. Hill
Event date
--
Software
--
Description
--
Description attachment
None