Media 000085637: Endocasts
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000085637: Endocasts
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000085637
Media type
Mesh
Object element or part
endocasts
Object represented
Object taxonomy
Tricentes crassicollidens
Object organization
Side
--
Orientation
--
Short description
Chriacus baldwini MCZ 20676 endocasts
Full description
Migrated MorphoSource 1 Media File Title: Chriacus baldwini MCZ 20676 endocasts Migrated MorphoSource 1 Media Group Title: Chriacus baldwini MCZ 20676
Creator
--
Date created
--
Date uploaded
September 03, 2019
FILE OBJECT DETAILS Field Definitions
File name
Chriacus_baldwini_MCZ_20676_endocasts_inner_ear-brain.stl
File format(s)
STL
File size
1.62 GB
Points
4306241
Polygons
8615120
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
22.766, 12.871, 38.231
Centroid coordinates
17.240, 8.660, 23.212
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Marie Skłodowska-Curie Actions, ERC, NSF
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Ornella Bertrand and colleagues provided access to these dataoriginally appearing in Bertrand et al., 2020 with data collections funded by H2020-MSCA-IF-2018-2020 (No. 792611). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MCZ:VP:VPM-20676
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000085636: Cranium [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000085636: Cranium [CTImageSeries] [CT]
was processed
to create
derived
Media 000085637: Endocasts [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000085637: Endocasts [Mesh] [CT] (this media)