Media 000089570: Proximal Humerus
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

Media preview currently unavailable. Please check back later.

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000089570
Media type
Mesh
Object element or part
Proximal humerus
Object represented
Object taxonomy
Homo sapiens
Side
Left
Orientation
--
Short description
Left proximal humerus PLY hi-res
Full description
Migrated MorphoSource 1 Media File Title: Left proximal humerus PLY hi-res Migrated MorphoSource 1 Media Group Title: Proximal humerus with osteomyelitis, healed fracture, trephination Migrated MorphoSource 1 Media File Description: Original CT was resampled to a z-axis resolution of 0.19458 microns in 3DSlicer. The Segment Editor in 3DSlicer was used to generate the PLY mesh, and Meshlab was used to remove loose pieces and apply ambient occlusion shading.\\r\\nV: 16,242,878\\r\\nF: 32,793,948
Creator
--
Date created
--
Date uploaded
October 07, 2019

FILE OBJECT DETAILS Field Definitions

File name
AFIP_1002671_fullres.ply
File format(s)
PLY
File size
654 MB
Points
16242878
Polygons
32793948
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
124.699, 71.352, 60.633
Centroid coordinates
-42.527, -47.908, 34.366
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, Federal Bureau of Investigation (Federal Bureau of Investigation)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nmhm:cw:AFIP-1002671 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Federal Bureau of Investigation (Federal Bureau of Investigation)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000089570: Proximal Humerus [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000089570: Proximal Humerus [Mesh] [Etc] (this media)