Media 000090364: Cranium
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000090364
Media type
Mesh
Object element or part
cranium
Object represented
Object taxonomy
Shoshonius cooperi
Side
NotApplicable
Orientation
--
Short description
Mesh file (STL)
Full description
Migrated MorphoSource 1 Media File Title: Mesh file (STL) Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
October 15, 2019

FILE OBJECT DETAILS Field Definitions

File name
Shoshonius-CM31366_.stl
File format(s)
STL
File size
196 MB
Points
2048991
Polygons
4101934
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
15.621, 23.115, 25.199
Centroid coordinates
8.649, 11.205, 13.795
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Carnegie Museum of Natural History, Section of Vertebrate Paleontoloogy
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1440742 (to DMB & GFG), NSF BSC 1440558 (to JIB), and NSF BCS 1552848 (to DMB)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by NSF BCS 1440742 (to DMB & GFG), NSF BSC 1440558 (to JIB), and NSF BCS 1552848 (to DMB). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object cm:vertpaleo:031366 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.500
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
2000
Voltage
145
Power
--
Amperage
67
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000056153: Cranium [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Doug Boyer, Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000056153: Cranium [CTImageSeries] [Etc] was processed to create derived Media 000090364: Cranium [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Doug Boyer, Mackenzie Shepard
Event date
May 03, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000090364: Cranium [Mesh] [CT] (this media)