Media 000098574: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000098574
Media type
Volumetric Image Series
Object element or part
head
Object taxonomy
Lialis burtonis
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1197\\r\\n\\r\\nMaisano:\\r\\nLialis: Scans of the head of Lialis burtonis (FMNH 166958) for Dr. Jessie Maisano of The University of Texas at Austin and ATOL. Specimen scanned by Matthew Colbert 14 March 2005.\\r\\n\\r\\n16bitrot: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.03021 mm), S.O.D. 44.3 mm, 1600 views, 2 samples per view, inter-slice spacing 2 lines (= 0.03021 mm), field of reconstruction 13.5 mm (maximum field of view 14.48889 mm), reconstruction offset 7300, reconstruction scale 1560. Acquired with 15 slices per rotation. Spike- and ring-removal processing done by Susan Garlock based on correction of raw sinogram data using IDL routines “RK_SinoDeSpike” and “RK_SinoRingProcSimul” with default parameters. Reconstructed with reconstruction angle of -5 degrees. Rotation correction processing done by Susan Garlock using IDL routine “DoRotationCorrection”. Total slices = 1095.\\r\\n
Creator
--
Date created
--
Date uploaded
January 11, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
647 MB
Image width
937
Image height
732
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.013180
Y pixel spacing
0.013180
Z pixel spacing
0.030210
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
585

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
The Field Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334961, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these dataoriginally appearing in Gauthier et al., 2012, with data collection funded by NSF EF-0334961 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Amphibians and Reptiles:166958 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1600
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000098574: Head [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000098574: Head [CTImageSeries] [Etc] (this media)