Media 000101035: Skull
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000101035
Media type
Mesh
Object element or part
Skull
Object represented
Object taxonomy
Aubria masako
Object organization
Side
--
Orientation
--
Short description
mesh file (obj)
Full description
Migrated MorphoSource 1 Media File Title: mesh file (obj) Migrated MorphoSource 1 Media Group Title: MicroCT volume and derivatives of mcz:herp:a-135999, Aubria masako
Creator
--
Date created
--
Date uploaded
February 15, 2020

FILE OBJECT DETAILS Field Definitions

File name
Aubria-masako-MCZ135999-skull.obj
File format(s)
OBJ
File size
43.9 MB
Points
592037
Polygons
1203718
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
29.473, 27.401, 12.417
Centroid coordinates
-3.292, 0.507, 0.413
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, Center for Nanoscale Systems (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Herp:A-135999 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
3200
Voltage
60
Power
0.010199999999999999
Amperage
170
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000101034: Whole Body [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000101034: Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000101035: Skull [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000101035: Skull [Mesh] [Etc] (this media)