Media 000105300: Ct Scan Of Body
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000105300: Ct Scan Of Body
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000105300
Media type
Mesh
Object element or part
CT scan of body
Object represented
Object taxonomy
Leptodactylus melanonotus
Object organization
Side
--
Orientation
--
Short description
skull
Full description
Migrated MorphoSource 1 Media File Title: skull
Creator
--
Date created
--
Date uploaded
March 05, 2020
FILE OBJECT DETAILS Field Definitions
File name
Leptodactylus_melanotus_2.stl
File format(s)
STL
File size
10.8 MB
Points
110414
Polygons
225520
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
14.237, 7.622, 13.355
Centroid coordinates
0.283, 0.576, -35.065
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Herp:169108
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.500093
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1300
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000049389: Ct Scan Of Body [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000049389: Ct Scan Of Body [CTImageSeries] [Etc]
was processed
to create
derived
Media 000105300: Ct Scan Of Body [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000105300: Ct Scan Of Body [Mesh] [Etc] (this media)