Media 000114159: Turbinates
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000114159
Media type
Volumetric Image Series
Object element or part
turbinates
Object represented
Object taxonomy
Speothos venaticus
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0383\\r\\n\\r\\nTheodor: \\r\\nSpeothoM: Scans of entire skull and close-up of turbinates of Speothos venaticus (male, MVZ 184054 (orig. 1268 M. H.), Tarpon Zoo, Tarpon Springs, Florida, 29 September 1970, M. Hildebrand), for Jessica Theodor and Blaire Van Valkenburgh of the Department of Organismic Biology, Ecology and Evolution, UCLA, in collaboration with Timothy Rowe of the University of Texas Department of Geological Sciences. Warp corrected scans of turbinates archived on a later disc.\\r\\n\\r\\nturb/16bit: Close-up of turbinates. Scanned by Matthew Colbert on 24 April 2001. 1024x1024 16-bit TIFF images. II, 150 kV, 0.16 mA, no filter, empty mount wedge, 160% offset, slice thickness 3 lines (= 0.207 mm), S.O.D. 120 mm, 1200 views, 6 samples per view, interslice spacing 3 lines (= 0.207 mm), field of reconstruction 37 mm (maximum field of view =60.903mm), reconstruction offset 470, reconstruction scale 97. Reconstructed offcenter, x = 0.8, y=0.2. Scanned in three-slice mode. \\r\\n\\r\\nUniversity of Texas High-Resolution X-ray CT Facility Archive 0384\\r\\n\\r\\nTheodor:\\r\\n\\r\\nSpeothoM: Warp corrected scans of close-up of turbinates of Speothos venaticus (male, MVZ 184054 (orig. 1268 M. H.), Tarpon Zoo, Tarpon Springs, Florida, 29 September 1970, M. Hildebrand), for Jessica Theodor and Blaire Van Valkenburgh of the Department of Organismic Biology, Ecology and Evolution, UCLA, in collaboration with Timothy Rowe of the University of Texas Department of Geological Sciences. 16bit and warp corrected scans of entire skull, and 16bit scans of turbinates, on Archive 0383.\\r\\n\\r\\nturb/warpcorr: The above images modified with IDL software “Unwarp v.1.0” written by Dr. Richard Ketcham to correct for radial distortion of images introduced by ACTIS scanning software. Corrected images are now 1031 pixels by 1031 pixels, resulting in a revised field of reconstruction of 37.253 mm.\\r\\n\\n\\nRelated URL: http://www.digimorph.org/specimens/Speothos_venaticus/ Migrated MorphoSource 1 Media Group Description: Related URL: http://www.digimorph.org/specimens/Speothos_venaticus/
Creator
--
Date created
--
Date uploaded
April 06, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
117 MB
Image width
1031
Image height
922
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.036000
Y pixel spacing
0.036000
Z pixel spacing
0.207000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
126

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MVZ:Mamm:MVZ:Mamm:184054 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
6
Projections
1200
Voltage
150
Power
--
Amperage
160
Surrounding material
empty mount
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114159: Turbinates [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000114159: Turbinates [CTImageSeries] [Etc] (this media)