Media 000115497: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000115497: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000115497
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Phalacrocorax auritus
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: CT scan of skull of Phalacrocorax auritus
Creator
--
Date created
--
Date uploaded
May 01, 2020
FILE OBJECT DETAILS Field Definitions
File name
OUVC_10644_Phalacrocorax-auritus.zip
File format(s)
ZIP archive, DICOM
File size
422 MB
Image width
602
Image height
543
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.090000
Y pixel spacing
0.090000
Z pixel spacing
0.090000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,590
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric eXplore Locus in vivo, Ohio University MicroCT Facility (Ohio University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Ohio University Vertebrate Collections
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF grants to L. M. Witmer: IOB-0517257, IOS-1050154, IOS-1456503
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Ohio University Vertebrate Collections provided access to these dataoriginally appearing in Early et al., 2020 , the collection of which was funded by NSF grants to L. M. Witmer: IOB-0517257, IOS-1050154, IOS-1456503.. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ouvc:10644
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Ohio University MicroCT Facility (Ohio University)
Creator
Ryan Ridgely
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
400000
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
7
Projections
1200
Voltage
80
Power
--
Amperage
450
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000115497: Skull [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Ryan Ridgely
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000115497: Skull [CTImageSeries] [Etc] (this media)