Media 000115895: Humerus
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000115895: Humerus
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000115895
Media type
Volumetric Image Series
Object element or part
humerus
Object represented
Object taxonomy
Hapalops elongatus
Object organization
Side
--
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: MicroCT Volume Migrated MorphoSource 1 Media File Description: Correct chirality
Creator
--
Date created
--
Date uploaded
May 08, 2020
FILE OBJECT DETAILS Field Definitions
File name
YPMPU_15160_Hapalops_elongatus_humerus.zip
File format(s)
ZIP archive, TIFF
File size
4.55 GB
Image width
1056
Image height
1170
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.055753
Y pixel spacing
0.055753
Z pixel spacing
0.055753
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,904
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Yale Peabody Museum
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
YPM:VP:YPM VPPU 015160
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Dr. Justin Gladman
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
200
Power
--
Amperage
210
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000115895: Humerus [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Dr. Justin Gladman
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000115895: Humerus [CTImageSeries] [CT] (this media)