Media 000116404: Windows Bitmap (Bmp) Image Series Zip File
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000116404
Media type
Volumetric Image Series
Object element or part
Windows bitmap (BMP) image series ZIP file
Object represented
Object taxonomy
Cryptothylax greshoffii
Object organization
Side
--
Orientation
--
Short description
CT_IVB-H-CD15-169
Full description
Migrated MorphoSource 1 Media File Title: CT_IVB-H-CD15-169 Migrated MorphoSource 1 Media Group Title: CT scan of whole specimen
Creator
--
Date created
--
Date uploaded
May 21, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, BMP
File size
2.77 GB
Image width
1536
Image height
1536
Color space
--
Color depth
8
Compression
None; BI_RGB; 0
X pixel spacing
--
Y pixel spacing
--
Z pixel spacing
--
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,944

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
CET Custom built Dual Source microCT, Laboratory of X-Ray Tomography in the Institute of Theoretical and Applied Mechanics, Centre of Excellence Telč (Czech Academy of Sciences)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: V. Gvoždík and colleagues provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object cd15:169 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Laboratory of X-Ray Tomography in the Institute of Theoretical and Applied Mechanics, Centre of Excellence Telč (Czech Academy of Sciences)
Creator
--
Event date
February 10, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.28
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2400
Voltage
120
Power
0.01
Amperage
83
Surrounding material
Agarose gel
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000116404: Windows Bitmap (Bmp) Image Series Zip File [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
February 10, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000116404: Windows Bitmap (Bmp) Image Series Zip File [CTImageSeries] [CT] (this media)