Media 000117131: Distal Tibia/Fibula
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000117131: Distal Tibia/Fibula
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000117131
Media type
Mesh
Object element or part
Distal Tibia/Fibula
Object represented
Object taxonomy
Homo sapiens
Object organization
Side
Right
Orientation
--
Short description
Distal Tibia/Fibula with Osteomyelitis/Healed Fracture PLY 75%
Full description
Migrated MorphoSource 1 Media File Title: Distal Tibia/Fibula with Osteomyelitis/Healed Fracture PLY 75% Migrated MorphoSource 1 Media Group Title: Distal Tibia/Fibula with Osteomyelitis/Healed Fracture Migrated MorphoSource 1 Media File Description: Half-resolution mesh was decimated another 50% in Meshlab.\\r\\n\\r\\nV: 4,506,190\\r\\nF: 9,156,068
Creator
--
Date created
--
Date uploaded
June 05, 2020
FILE OBJECT DETAILS Field Definitions
File name
AFIP1002694_75per.ply
File format(s)
PLY
File size
234 MB
Points
4506190
Polygons
9156068
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
68.057, 74.059, 221.657
Centroid coordinates
-38.280, -40.883, 155.889
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, Federal Bureau of Investigation (Federal Bureau of Investigation)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nmhm:cw:AFIP-1002694
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Federal Bureau of Investigation (Federal Bureau of Investigation)
Creator
--
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000117131: Distal Tibia/Fibula [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None