Media 000133908: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000133908
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Gymnelopsis ocellatus
Object organization
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
July 21, 2020

FILE OBJECT DETAILS Field Definitions

File name
USNM_Fish_92588.zip
File format(s)
ZIP archive, TIFF
File size
275 MB
Image width
197
Image height
399
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.075070
Y pixel spacing
0.075070
Z pixel spacing
0.075070
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,980

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
Blackburn, D.C., et al. 2024. Increasing the impact of vertebrate scientific collections through 3D-imaging: the openVertebrate (oVert) Thematic Collections Network. BioScience 74: 169–186. https://doi.org/10.1093/biosci/biad120; Migrated MorphoSource 1 Media Citation Instructions: Smithsonian National Museum of Natural History provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:FISH:USNM 92588 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
480
Voltage
100
Power
0.022
Amperage
220
Surrounding material
None
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000133908: Whole Body [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Zachary Randall
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000133908: Whole Body [CTImageSeries] [Etc] (this media)