Media 000141273: Pelvis
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000141273: Pelvis
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000141273
Media type
Mesh
Object element or part
pelvis
Object represented
Object taxonomy
Aplodontia rufa
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Micro-CT volume and derivative mesh files
Creator
--
Date created
--
Date uploaded
July 28, 2020
FILE OBJECT DETAILS Field Definitions
File name
Aplodontia-rufa-FMNH-60775-pelvis.ply
File format(s)
PLY
File size
111 MB
Points
1483018
Polygons
2966150
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
33.608, 31.449, 57.289
Centroid coordinates
97.276, 28.270, 123.023
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Field Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
--
Cite as
Roger Benson provided access to these data, originally appearing in … , the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:Mammals:60775
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Neander
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1800
Voltage
100
Power
--
Amperage
300
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000141266: Element Unspecified [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
April Neander
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000141266: Element Unspecified [CTImageSeries] [Etc]
was processed
to create
derived
Media 000141273: Pelvis [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
April Neander
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000141273: Pelvis [Mesh] [Etc] (this media)