Media 000158821: Skeletons
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000158821: Skeletons
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000158821
Media type
Volumetric Image Series
Object element or part
Skeletons
Object represented
Object taxonomy
Filikomys primaevus
Object organization
Side
--
Orientation
--
Short description
MOR 10908 "Block 1" Pt. 1
Full description
Migrated MorphoSource 1 Media File Title: MOR 10908 "Block 1" Pt. 1 Migrated MorphoSource 1 Media Group Title: MOR 10908, Filikomys primaevus skeletons, from Weaver et al. (2020)
Creator
--
Date created
--
Date uploaded
August 26, 2020
FILE OBJECT DETAILS Field Definitions
File name
3LittleMultis.zip
File format(s)
ZIP archive, TIFF
File size
265 MB
Image width
1929
Image height
1816
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.053900
Y pixel spacing
0.053900
Z pixel spacing
0.053900
Pixel spacing units
--
Slice thickness
--
Number of images in set
761
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, X-ray Computed Tomography Facility (University of Washington)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Montana State University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mor:10908
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
X-ray Computed Tomography Facility (University of Washington)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000158821: Skeletons [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000158821: Skeletons [CTImageSeries] [Etc] (this media)