Media 000158908: Capitate
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000158908
Media type
Mesh
Object element or part
capitate
Object represented
Object taxonomy
Adapis parisiensis
Side
Left
Orientation
--
Short description
capitate mesh
Full description
Migrated MorphoSource 1 Media File Title: capitate mesh Migrated MorphoSource 1 Media Group Title: derivative surface files Migrated MorphoSource 1 Media File Description: This model was created by merging two CT scan derived surfaces of opposing "half casts" in Geomagic software.
Creator
--
Date created
--
Date uploaded
August 28, 2020

FILE OBJECT DETAILS Field Definitions

File name
Adapis_Capitate_1_6_FIN.ply
File format(s)
PLY
File size
5.38 MB
Points
81828
Polygons
160438
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5.339, 7.734, 4.507
Centroid coordinates
12.877, 29.270, 85.845
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object rnngl:rd:311 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
70
Power
--
Amperage
114
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000158908: Capitate [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000158908: Capitate [Mesh] [Etc] (this media)