Media 000165933: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000165933
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Aneides iecanus
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
October 27, 2020

FILE OBJECT DETAILS Field Definitions

File name
MVZ_H_203564.zip
File format(s)
ZIP archive, TIFF
File size
602 MB
Image width
358
Image height
947
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.032447
Y pixel spacing
0.032447
Z pixel spacing
0.032447
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
5,020

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; oVert TCN; NSF DBI-1701797
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of California-Berkeley provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MVZ:Herp:MVZ:Herp:203564 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1380
Voltage
80
Power
0.0192
Amperage
240
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000165933: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Zachary Randall
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000165933: Whole Body [CTImageSeries] [CT] (this media)