Media 000346137: Calvarium
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

GENERAL DETAILS Field Definitions

Media ID
000346137
Media type
Mesh
Object element or part
Calvarium
Object represented
Object taxonomy
Homo neanderthalensis
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
February 23, 2021

FILE OBJECT DETAILS Field Definitions

File name
Engis2_isosurface_dec_enhanced.ply
File format(s)
PLY
File size
16.7 MB
Points
459719
Polygons
919362
Map type
Normal
UV coordinates
False
Vertex color
False
Bounding box dimensions
131.008, 278.807, 255.879
Centroid coordinates
-1.980, -205.168, -174.907
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Somatom Sensation 64, Erasme Hospital (Brussels' Université Libre)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ulg:pa:Engis2 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Erasme Hospital (Brussels' Université Libre)
Creator
--
Event date
February 23, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000346137: Calvarium [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Albessard-Ball, Lou
Event date
February 23, 2021
Software
--
Description
Volumetric rendering
Description attachment
None

Media produced by this event on MorphoSource

Media 000346137: Calvarium [Mesh] [CT] (this media)