Media 000346177: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000346177: Element Unspecified
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000346177
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Brookesia griveaudi
Object organization
Side
--
Orientation
--
Short description
Brookesia griveaudi
Full description
Brookesia griveaudi specimen indicated by "hollow L" marker
Creator
--
Date created
--
Date uploaded
February 23, 2021
FILE OBJECT DETAILS Field Definitions
File name
Brookesia_griveaudi_ZFMK_62325_ChameleonTube30.zip
File format(s)
ZIP archive, BMP
File size
1.11 GB
Image width
840
Image height
844
Color space
--
Color depth
8
Compression
0; BI_RGB; None
Series type
Reconstructed image stack
X pixel spacing
0.035100
Y pixel spacing
0.035100
Z pixel spacing
0.035100
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,689
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Christopher V. Anderson (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
The collection of this scan was funded by the University of South Dakota; NSF DBI-1701665
Publisher
--
Cite as
Christopher V. Anderson provided access to these data originally appearing in MorphoSource, the collection of which was funded by University of South Dakota. The files were downloaded from www.MorphoSource.org, Duke University
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
zfmk:62325
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Anderson, Christopher V.
Event date
March 23, 2021
Software
--
Description
Specimen identified by radiopaque "hollow L" marker
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000346177: Element Unspecified [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Anderson, Christopher V.
Event date
February 23, 2021
Software
--
Description
Specimen identified by radiopaque "hollow L" marker
Description attachment
None
Media produced by this event on MorphoSource
Media 000346177: Element Unspecified [CTImageSeries] [CT] (this media)